Friday, January 13, 2012

Full flow system,A full flow type oil system.


Full flow system
Fig. 8-2 A full flow type oil system.

7. Although the pressure relief valve system operates satisfactorily for engines which have a low
bearing chamber pressure, which does not unduly increase with engine speed, it becomes an
undesirable system for engines which have high chamber pressures. For example, if a bearing
chamber has a maximum pressure of 90 lb. per sq. in. It would require a pressure relief valve setting of
130 lb. per sq. in. to produce a pressure drop of 40 lb. per sq. in. at the oil feed jet. This results in theneed for large pumps and difficulty in matching the required oil flow at slower speeds.